SUPER B-VENT GAS FIREPLACE
INSTALLATION AND OPERATING INSTRUCTIONS
MODELS: BV(4536,5142)(N,P)(V,E)B
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED OUT OF
TRAFFIC AND AWAY FROM FURNITURE
AND DRAPERIES.
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURE AND SHOULD
STAY AWAY TO AVOID BURNS OR
CLOTHING IGNITION.
YOUNG CHILDERN SHOULD BE
SUPERVISED WHEN THEY ARE IN THE
SAME ROOM AS THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED ON
OR NEAR THE APPLIANCE.
KEEP THE ROOM AREA CLEAR AND FREE
FROM COMBUSTIBLE MATERIALS,
GASOLINE, AND OTHER FLAMMABLE
VAPORS AND LIQUIDS.
READ BEFORE INSTALLING OR OPERATING AND SAVE THESE INSTRUCTIONS
WARNING: If the information in these
instructions are not followed exactly, a fire or
explosion may result causing property
damage, personal injury or death.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building;
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
This appliance may be installed in an aftermarket,
p
ermanently located, manufactured home or mobile home,
where not prohibited by local codes.
This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use
with other gases, unless a certified kit is used.
For Residential Use-Meets All HUD Requirements For
Manufactured Housing Installations
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - SUPER B-VENT GAS FIREPLACE

SUPER B-VENT GAS FIREPLACEINSTALLATION AND OPERATING INSTRUCTIONSMODELS: BV(4536,5142)(N,P)(V,E)BDUE TO HIGH TEMPERATURES, THEAPPLIANCE SHOULD BE LOCA

Page 2 - TABLE OF CONTENTS

PRE-INSTALLATION INFORMATIONPRE -I NSTAL LA TIO N INF ORM AT ION9CAUTIONMeasure fireplace dimensions and verify framing methods & wall covering d

Page 3 - IMPORTANT SAFETY INFORMATION

VENT INSTALLATIONVENT IN STAL LATION10VENT INSTALLATION:WARNINGThe following venting instructions are provided as a general guideline. Always check

Page 4

VENT INSTALLATIONVENT IN STAL LATION11WARNINGNever use more than two (2) 45 degree elbows. When using adjustable elbows, never exceed 45 degrees.Ve

Page 5

VENT INSTALLATIONVENT IN STAL LATION12Figure 8: Installing Pipe SupportsWARNINGAlways maintain minimum clearances around vent systems. The minimum c

Page 6

VENT INSTALLATIONVENT IN STAL LATION13 Figure 9: Ceiling Firestop LocationVent Termination:For Vertical Termination` Figure 10: Minimum Vent Height

Page 7

VENT INSTALLATIONVENT IN STAL LATION14NOTEWhen working on the roof, cover the opening of the installed vent pipes below to prevent debris falling in

Page 8

GAS LINE AND ELECTRICAL INSTALLATIONGAS LINE AND ELECTRICAL INSTALLATION15GAS LINE AND ELECTRICALGas Line Installation:NOTEPlumbing connections sh

Page 9

GAS LINE AND ELECTRICAL INSTALLATIONGAS LINE AND ELECTRICAL INSTALLATION16Figure 12: Gas Pressure Check at Gas ValveElectrical Wiring:Standing Pil

Page 10 - PRE-INSTALLATION INFORMATION

GAS LINE AND ELECTRICAL INSTALLATIONGAS LINE AND ELECTRICAL INSTALLATION17 Figure 13: Wiring Diagram for Standing Pilot - Millivolt SystemOptional

Page 11 - VENT IN STAL LATION

GAS LINE AND ELECTRICAL INSTALLATIONGAS LINE AND ELECTRICAL INSTALLATION18• Turn RS-ON-OFF switch to the “ON” position. If meter is reading mor

Page 12

TABLE OF CONTENTSTABLE OF CONTENTS1IMPORTANT SAFETY INFORMATION: ...

Page 13

GAS LINE AND ELECTRICAL INSTALLATIONGAS LINE AND ELECTRICAL INSTALLATION19NOTERemote receiver must be mounted outside the appliance, due to high t

Page 14

FINAL INSTALLATIONFI NAL INST ALLAT ION20FINAL INSTALLATIONWall Finishing:Definitions:Combustible Materials - Materials made of or surfaced with wood

Page 15

FINAL INSTALLATIONFI NAL INST ALLAT ION21Log Placement for fiber VDY24/18D3R:Step 1: Line up pins on bottom of Rear Log #1 with pins ongrate bar and

Page 16

FINAL INSTALLATIONFI NAL INST ALLAT ION22Glass Bi-Fold Door Installation:WARNINGGlass doors must be installed on all Propane/LPG units and operated i

Page 17

FINAL INSTALLATIONFI NAL INST ALLAT ION23Damper operation:NOTEFor Massachusetts residents only: Installation of this vented gas fireplace in the Comm

Page 18

OPERATING INSTRUCTIONSOPE RAT ING INS TRU CTI ONS24Before Lighting the Fireplace:• Read the IMPORTANT SAFETY INFORMATION section at the beginning o

Page 19

OPERATING INSTRUCTIONSOPE RAT ING INS TRU CTI ONS25PilotLIGHTING INSTRUCTIONSMILLIVOLT CONTROL8. With the control knob pushed in, push in andreleas

Page 20

OPERATING INSTRUCTIONSOPE RAT ING INS TRU CTI ONS26FOR YOUR SAFETY READ BEFORE LIGHTINGWARNING:If you do not follow these Instructions exactly, a fi

Page 21 - FI NAL INST ALLAT ION

MAINTENANCEMAI N T E N A N C E27MAINTENANCEWARNINGTurn off gas before servicing fireplace. It is recommended that a qualified service technician perfo

Page 22

MAINTENANCEMAI N T E N A N C E28Vent System:The fireplace and venting system should be inspected before initial use and at least annually by a qualifi

Page 23

IMPORTANT SAFETY INFORMATIONIMPORTANT SAFET Y INFORMA TION2IMPORTANT SAFETY INFORMATION:INSTALLER: Please leave these instructions with the owner.O

Page 24

PARTS LIST / ILLUSTRATIONSPARTS LIST / ILLUSTRATIONS29PARTS LIST / ILLUSTRATIONBFirebox Components: Standard and Accessories Item Description Qty 4

Page 25 - OPERATING INSTRUCTIONS

PARTS LIST / ILLUSTRATIONSPARTS LIST / ILLUSTRATIONS30Engine Components:Standing Pilot – Millivolt ControlItem Description Qty 4536NV 4536PV 5142NV

Page 26

31Electronic Ignition ControlItem Description Qty 4536NE 4536PE 5142NE 5142PE1Gas Valve Assembly 1 37D0016 37D0017 37D0016 37D00172Pilot Assembly 1 54

Page 27

32TROUBLESHOOTINGSTANDING PILOT - MILLIVOLTSYMPTOM POSSIBLE CAUSE REMEDY1. Spark ignitor willnot light pilot afterrepeated triggeringof piezo.A. Wir

Page 28 - MAI N T E N A N C E

33ELECTRONIC IGNITION

Page 29

341. Glass Soots A. Flame impingementon logsInstall log set per the instructionsInspect the injector and air intake area. Make sure this areadoes n

Page 30 - PARTS LIST / ILLUSTRATIONS

35LIMITED LIFETIME WARRANTY POLICYLifetime WarrantyThe following components are warranted for life to the original owner, subject to proof of purchase

Page 31

PRODUCT SPECIFICATIONS/LISTING & CODE APPROVALPRODUCT SPECIFICATIONS/LISTING & CODE APPROVAL3PRODUCT SPECIFICATIONS:Gas Pressure (Inches W

Page 32 - SPNK3642E

PRE-INSTALLATION INFORMATIONPRE -I NSTAL LA TIO N INF ORM AT ION4PRE-INSTALLATION INFORMATION:Before You Start:Read this homeowner manual thoroughly

Page 33 - 4. Frequent pilot

PRE-INSTALLATION INFORMATIONPRE -I NSTAL LA TIO N INF ORM AT ION5 Figure 1: Fireplace Dimensions

Page 34 - ELECTRONIC IGNITION

PRE-INSTALLATION INFORMATIONPRE -I NSTAL LA TIO N INF ORM AT ION6Figure 2: Fireplace Locations and Minimum Clearances RequirementsCAUTION: Measure fi

Page 35

PRE-INSTALLATION INFORMATIONPRE -I NSTAL LA TIO N INF ORM AT ION7Figure 3: Wall & Ceiling Minimum ClearancesWall and Ceiling Clearance Requiremen

Page 36

PRE-INSTALLATION INFORMATIONPRE -I NSTAL LA TIO N INF ORM AT ION8Mantel Clearances:If a combustible mantel is installed, it must meet the clearance r